Aquatic Infinity Series Hot Tub User Manual


 
16 AQUATIC INDUSTRIES, INC.
INFINITY ON/OFF WITH HEATER CONTROL (SEE DIAGRAM 6A):
1. To Turn Pump On: Pressing the On/Off button will turn the pump on. Pressing a second time
will turn the pump off. A built-in timer will turn the pump and heater off after 20 minutes.
2. To Change Temperature: The heater and buttons are used to set water temperature. When
pressed, the display shows the actual set point. By pressing up or down, the set point can be
changed. Keeping the buttons pressed changes the setting continuously. The temperature can
vary from 90° to 104° F.
Note: The set point light (sp) is “On” when the display shows the set point and “Off” when it shows
the actual water temperature. The heater’s LED will blink when the system calls for heat and will
stay on when the heater is “On”. The control turns the heater “On” when the temperature reaches
the set point —1° F and keeps it on until it reaches the set point +1° F.
3. For Infinity I: To Turn Continuous Waterfall On: Pressing and holding down the chromatherapy button
for 2 seconds will turn the continuous waterfall on. Depressing the chromatherapy button for 2 seconds
with the continuous waterfall on will turn off the
waterfall. However, the light output will automatically
turn off after 2 hours; the continuous waterfall will
automatically turn off after 20 minutes. Note: The
continuous waterfall is only featured on the Infinity I.
Other Features:
When power is on, the control displays “000” for
five seconds and then blanks itself.
When the pump is shut off, the display shows the
water temperature for a period of 15 minutes.
The High-Limit circuit will shut the heater off if the
temperature of the water at the High-Limit sensor
reaches 119° F. Should this occur, the display will
show “• • • ” but the pump will still be allowed to work. Only the heater will be shut off. In order for the
heater to be reactivated the user must reset circuit breaker when the temperature has fallen below 119° F.
When the pump is on, the display will normally show the current water temperature reading and the
remaining minutes on the timer. This will toggle every 5 seconds.
OPERATION of
INFINITY SERIES WHIRLPOOLS
NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD
BE 2" ABOVE HIGHEST JET.
BATHSIDE CONTROL SYSTEMS:
Set Point Indicator
Heater On Indicator
6A