A SERVICE OF

logo

Interfaces
\text/etd/DA615\Interfaces
6.4 DA615 instruction manual
RS-232-C serial interface
The DA615 printer has a standard RS-232-C serial interface that is compatiblewith
with most computers and terminals.
Connecting
socket
The DA615 printer is equipped with a standard DB-9 serial connection
socket.
Pin assignment
PIN Signal Signal- Meaning
Input/Output
1 --- - Free
2 R x d E Receive data
3 T x d A Transmit data
4 DTR A Clear to receive
5 GND - Signal ground
6 --- - Free
7 RTS A +12V
8 CTS E Clear to send
9 --- - Free
Pin 2
Received Data (RxD):
Serial data transfer from computer to printer.
Pin 3
Transmitted Data (TxD):
Serial data transfer from printer to computer system or terminal (e.g.
X
ON
/X
OFF
characters).
Pin 4
Data Terminal Ready (DTR):
Printer output that clears data transfer to the printer or aborts i
t
(handshaking). Data transfer is possible when DTR is high. It is no
t
possible when DTR is low.
Pin 5
Signal Ground (GND):
This is the reference potential for the entire data exchange.
Pin 7
Request to Send (RTS):
This signal is always high when the printer is switched on.
Pin 8
Clear to Send (CTS):
Printer input that clears or aborts data transmission to the computer.
When the input is high, the printer can transmit data. This input mus
t
always be high for software handshaking with Xon/Xoff.