Instruction Set 9-109
mfcr
Move From Condition Register
mfcr
Move From Condition Register
(RT) (CR)
The contents of the CR are placed into register RT.
If instruction bit 31 contains 1, the contents of CR[CR0] are undefined.
Registers Altered
•RT
Invalid Instruction Forms
Reserved fields
Architecture Note
This instruction is part of the PowerPC User Instruction Set Architecture.
mfcr RT
31 RT 19
0 6 11 21 31