NOTE:
9 “–” means below.
9 Application wattage indicates when each device is
used by itself.
9 The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
9 The overload indicator light 1 comes on when
total wattage exceeds the application range. (See
page 18 for more details.)
– 16 –
AE01000
APPLICATION RANGE
AC DC
Power factor 1 0.8–0.95
0.4–0.75
(Efficiency 0.85)
EF2800i
–2,500W –2,000W –850W
YG2800i
Rated voltage
12V
Rated current
10A
760-021a
q
Generator rated output 2500VA
Frequency Power factor
1.0 –2350W
AC
0.8 –1880W
120W
DC —
(12V/10A)
cC
Be sure the total load is within generator rated output otherwise generator dam-
age will occur.
NOTE:
Some precision equipment is voltage sensitive and may require a more uniform voltage
supply than portable generators provide. Examples include some medical equipment,
personal computers, and some inverters that sense peak and RMS voltage values.
Consult the precision-equipment vendor before relying on any portable generator to pro-
vide power to such equipment.