Yamaha yamaha generator Portable Generator User Manual


 
AE00780
DC PROTECTOR
The DC protector turns off automatically when the load
exceeds the generator rated output.
cC
Reduce the load to the specified generator rated
output if the DC protector turns off. If it turns off
again, consult a Yamaha dealer.
NOTE:
Press to reset the DC protector.
1 OFF
2 ON
11
763-188a
q
w
763-006
w
q
763-105a
763-060a
e
AE00848
G.F.C.I. RECEPTACLE
(for YG2800i)
The G.F.C.I. (Ground Fault Circuit Interrupter) 1 shuts
off power to the protected receptacles if a ground fault
(electrical leak) is detected.
If the reset button 2 pops out 3, the equipment
plugged into the receptacle may be faulty. If this hap-
pens, check the equipment carefully. If the equipment
appears to be in good condition, press the reset button
firmly until a click is heard. This will restore power. If
the reset button pops out again, unplug the equipment
immediately. Have the equipment inspected and
repaired by a qualified repairperson before attempting
to use it again.
w
TO REDUCE THE CHANCE OF ELECTRICAL
SHOCK:
9 Do not attempt to operate equipment if the
ground fault circuit interrupter reset button
pops out repeatedly during use.
9 Test the ground fault circuit interrupter during
the pre-operation checks according to the
maintenance instructions on page 30.
9 Remember that only receptacles labeled
“GFCI” have ground fault circuit interrupter
protection.
7VU-9-12-A 10/9/03 11:59 AM Page 11