Yamaha EF3000iSE, EF3000iSEB Portable Generator User Manual


 
34
707-102a
q
712-028a
AE00601
STORAGE
Long term storage of your machine will require some
preventive procedures to guard against deterioration.
AE01056
DRAIN THE FUEL
1. Remove the fuel tank cap. Drain the fuel from the
fuel tank into an approved gasoline container using
a commercially available hand siphon.Then, install
the fuel tank cap.
w
9 Fuel is highly flammable and poisonous. Check
SAFETY INFORMATION(See page 5) careful-
ly.
9 Wipe up any spilled fuel immediately.
2. Drain fuel from the carburetor by loosening the
drain screw 1 on the carburetor float chamber.
3. Turn the fuel cock knob to OFF. Start the engine
and leave it run until it stops.
This will burn any remaining fuel in the carburetor.
AE01079
ENGINE
1. Remove the spark plug, pour about one table-
spoon of SAE 10W30 or 20W40 motor oil into the
spark plug hole and reinstall the spark plug. Recoil
start the engine by turning over several times (with
ignition off) to coat the cylinder walls with oil.
2. Pull the recoil starter until you feel compression.
Then stop pulling. (This prevents the cylinder and
valves from rusting).
3. Clean exterior of the generator and apply a rust
inhibitor.
4. Store the generator in a dry, well-ventilated place,
with the cover placed over it.
5. The generator must remain in a vertical position
when stored, carried or operated. The caster lock
lever should be in the LOCKposition when stored
or operated.
712-029b
7CH-9-10-b 6/18/04 5:58 PM Page 34