Yamaha EF3000iSE, EF3000iSEB Portable Generator User Manual


 
16
cC
9 Take your hand off the switch immediately after
the engine starts.
9 If the engine fails to start, release the switch,
wait a few seconds, then try again. Each
attempt should be as short as possible to pre-
serve the battery. Do not crank the engine more
than 10 seconds on any one attempt.
4. After the engine starts, warm up the engine until
the engine does not stop when the choke knob is
returned to the original position.
5. Push the choke knob back to the original position.
NOTE:
When starting the engine in areas where the ambient
temperature is below 0°C (32°F), the engine automati-
cally operates at the rated r/min (3,800 r/min) for three
minutes to warm up the engine regardless of the econ-
omy control switch position. The economy control unit
operates normally afterwards if the economy control
switch is turned to I(ON).
763-120a
q
704-018
701-049c
Manual Starting:
3. Turn the engine switch to the 7(ON) position.
1 7 ON
4. Pull slowly on the recoil starter until it is engaged,
then pull it briskly.
5. After the engine starts, warm up the engine until
the engine does not stop when the choke knob is
returned to the original position.
6. Push the choke knob back to the original position.
7CH-9-10-a 5/18/04 2:22 PM Page 16