Wybron N/A Landscape Lighting User Manual


 
17
will control the fan speed. See the Coloram II Power Supply
manual for details.
2. Low -- for quietest operation.
3. Norm (Normal speed) -- for longest gel life
Error Messages
The CXI can display error messages as follows:
1. Roll Call -- this is displayed when the power supply is plugged in and the CXIs
are waiting for the power supply to request each CXI to "report in".
2. The following messages are related to gel string initialization:
a. front gel too short - rollers stalled before the end of the gel string was
reached
b. front gel too long - gel string came loose from a roller
c. back gel too short - rollers stalled before the end of the gel string was
reached
d. back gel too long - gel string came loose from a roller
3. Low Volt (low voltage) there is less than 17VDC at the CXI. This is a warning that
the voltage is dangerously low. This is normally a "head-feet" cable problem.
4. Shut Down - there is less than 16 VDC at the CXI and the unit
has shut down because it cannot work properly below this
voltage. This is normally a "head-feet" cable problem or the
user has commanded a "shut down" from the power supply.
5. Mtrs Errs (Motors Errors) -- both motors cannot get to their
commanded position because the roller is jammed or the
rotary encoder has failed.
6. Mtr1 Err (Motor 1 Error) -- motor #1 cannot get to its commanded position
because the roller is jammed or the rotary encoder has failed.
7. Mtr2 Err (Motor 2 Error) -- motor #2 cannot get to its commanded position
because the roller is jammed or the rotary encoder has failed.
8. XRAM Fail (Nonvolitile RAM failure) -- the memory device which saves the menu
settings after power down has failed.