Topcon GTS-823A Telescope User Manual


 
8-3
8 PARAMETERS SETTING MODE
8.1.2 Parameters for communication
Serial port
.
Setting parameters for RS232C
Setting parameter for RC
Menu Selecting Item Contents
S.Port
RS232C
/RC
Selecting serial port, RS-232C connector 1(6pins) or Remote
controll system.
Menu Selecting Item Contents
B. Rate
1200
/ 2400 / 4800 /
9600
Select the baud rate.
Data. L
7
/ 8 Select the data length seven digits or eight digits.
Parity none / odd /
even
Select the parity bit.
Stop Bit
1
/ 2 Select the stop bit.
Delimit
ETX
/ CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
REC-A/B
A
/ B
Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
Protocol OFF /
ON
When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard
NEZ-REC
Std
/ Exp
Record coordinates in standard or Data with slope distance
and horizontal angle data.
Trk Stat
OFF
/ ON
Selecting additional information of utility to measuring data
such as tracking status or not.
If such utility is selected, electric circular level graphic will not
be displayed whenever tilted over.
OFF :No additional information
ON :Additional information
Menu Selecting Item Contents
Channel
1
/ 2 / 3
Sets communication channel when using with remote controll
system.
V.Search
15
/ 30
Selecting the vertical range for searching a prism when using
with remote controll system.
15 : ±15
°
30 : ±30
°
RC
S
/ M
Selecting the number of the RC-2RII to use one or more than
one when using with RC-2RII.
S : Single RC-2RII use
M : Multiple RC-2RII use
The following settings are effective for standard measurement modes only.
You are requested to set each time of each application such as EXTERNAL LINK (in Program
modes) or other application software.