Stow G-4.5R Portable Generator User Manual


 
STOW G-4.5R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #3 (03/13/06) — PAGE 15
OPERATION AND SAFETY DECALS (S/N 5498031 AND ABOVE)
Figure 2B. Operation and Safety Decals (S/N 5498031 and Above)
Before connecting this generator to any building’s
electrical system, a licensed electrician must install
an isolation (transfer) switch.
Serious injury or death may result without this
transfer switch.
WARNING!
P/N 0820610404
CONTACT
STOW PARTS DEPT.
MODEL
SERIAL NO.
Only qualified personnel should
install, use or service this
equipment.
DANGEROUS
GAS
S-4984
WARNING
Only operate machine in well ventilated
areas.
DO NOT inhale exhaust gases.
Only qualified personnel should
install, use or service this
equipment.
DANGEROUS
GAS
S-4985
DANGER
Do not touch output terminals or
internal wiring while unit is operating.
Turn off power before servicing.
Only qualified personnel should
install, use or service this
equipment.
P/N 8700611904
P/N 8700611804
ON
ON
S-3704
P/N 1980680004
FUEL COCK
CAUTION
OPERATE AT
3600 RPM ONLY
()
FULL THROTTLE
DAMAGE MAY RESULT IF
OPERATED AT LOWER SPEEDS
P/N 7900636004
P/N 0800628504
S-1123
P/N A92120000
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the “OFF” position.
3. Open the fuel valve.
4. Close the choke with the choke lever.
5. Turn the operation switch to the “ON” position
6. Pull the recoil starter.
7. After the engine starts, gradually push in the choke valve.
8. Run the generator for 3-5 minutes without load.
9. Check for any abnormal noise or smell.
10.Switch the circuit breaker to the “ON” position.
11. When stopping, remove the load for 2-3 minutes before
stopping engine.
12. Turn the operation switch to the “OFF” position.
13. After the engine completely stops. Close the fuel valve.
OPERATING INSTRUCTIONS
P/N 35137
P/N A4511200402
To avoid injury,
you MUST read
and understand
operator’s manual
before using this
machine.
Ask for training
as needed.
This machine to
be operated by
qualified
personnel only.
P/N 35137
WARNING
A92120000
OPERATION
SWITCH
ON
OFF
20A
IDLE
CONTROL
ON
OFF
AC CIRCUIT
BREAKER
AC VOLTMETER
30A
20A
120/240V
120V
20A
120V
240/120V
FULL POWER
SWITCH
G-4.5R
P/N A4561000203