Problem Cause Solution
Engine will not start Battery not connected. Attach battery cables, check wires.
Weak battery. Test battery, charge or replace.
No fuel. Add fuel.
Fuel lter plugged. Replace fuel lter.
Defective spark plugs.
Low Engine Oil
Remove plugs, check gap, clean or
replace.
Check Oil Level
Flow Control Levers in the “ON”
position.
Move the levers to the off position.
Fluid blowing out of uid reservoir
vent.
Hydraulic tank overlled. Correct the uid level.
Pump suction leak. Check suction connections. Tighten
if necessary.
Hydraulic tool won’t operate. Flow control lever(s) not in the (ON)
position.
Check that the ow control lever(s)
are in the ON position.
Incorrect hose connection to tool. Make sure the tool hose circuit
goes from left (pressure) tting to
tool and back to the right tting
(return). Fluid always ows from the
male to female ttings.
Quick disconnect ttings defective. Detach from hose, connect set
together and check for free ow.
Hydraulic uid level low. Check for correct uid level. Fill
using the recommended uid.
Relief valve stuck open. Adjust or replace valve.
Suction hose kinked. Make sure suction hose from
uid reservoir to pump inlet has a
smooth curve.
Tool is defective. Refer to tool manual.
TROUBLESHOOTING