– 24 –
Battery
cables
Fuel
strainer
(3) Remove the fuel strainer.
[ For electric start models ]
(4) Remove the battery cover and disconnect battery
cables.
(5) Remove the battery from frame.
5-3-4 GROUNDING WIRE
Remove the grounding wire at the right bottom side of
control panel.
M6 Nut 1pce.
Choke wire
5-3-5 CHOKE WIRE
Loosen the screw that fixes the choke wire to carburetor
choke lever.
Turn the engine switch to “CHOKE” position to
disconnect the choke wire from the choke lever.
Tools : Screw driver
5-3-6 CONTROL PANEL and INVERTER UNIT
(1) Loosen the four screws and remove the upper
front cover.
M6 x 18mm Screw : 4pcs.
(2) Loosen the two bolts and remove the lower front
cover.
M6 x 18mm Flange bolt : 2pcs.
Tools : Screw driver