Subaru Robin Power Products RG2800IS Portable Generator User Manual


 
– 42 –
5-4-12 CARBURETOR
(1) Install the Sponge Insulator around the intake flange.
5-4-13 AIR CLEANER BASE
Attach the Air Cleaner Base to the carburetor and fix with
two M6 bolts and one M6 Flange bolt.
M6 Flange nut : 2 pcs.
M6 x 20mm Flange bolt : 1 pce.
5-4-14 AIR CLEANER ELEMENT
Assemble the Air Cleaner Element and the Air Cleaner
Cover to the air cleaner base.
Wash the cleaner element if it is dirty before reassembly.
(2) Install the Carburetor to the intake flange.
NOTE: Be sure to attach the gasket between the
carburetor and the intake flange.
Cleaner cover
Element
Air cleaner
Carburetor
Sponge insulator
Tightening torque : 6.0
-
8.0 N
m
60
-
80 kgf
cm
(4.4
-
5.9 ft
lbs)