5-3-22 RECOIL STARTER
Loosen the three M6 bolts and remove the recoil
starter.
M6 x 18mm Flange bolt : 3pcs.
Tools : 10mm Box wrench
NOTE : Refer to section 5-5 for further instruction for
disassembly/reassembly procedures of recoil
starter.
Recoil starter
5-3-23 BOTTOM EXTENSION PLATE
Loosen the four M8 bolts and remove the bottom
extension plate.
M8 x 33mm Flange bolt for crankcase side : 2 pcs.
M8 x 12mm Flange bolt for blower housing side : 2 pcs.
Tools : 12mm Box wrench
Bottom extension plate
5-3-24 BLOWER HOUSING
(1) Loosen the four M& bolts and remove the
Separator (A/C) and Separator (SEL) from Blower
Housing. (for the soundproof type only)
M6 x 8mm Flange bolt : 3pcs.
M6 x 12mm Flange bolt: 1 pce.
Tools : 10mm Box wrench
(2) Loosen the four M6 bolts and remove the blower
housing.
M6 x 35mm Bolt : 1pce.
M6 x 45mm Bolt : 3pcs.
Tools : 10mm Box wrench
Blower housing
M6x35mm Bolt
M6x45mm
Bolt
Separator
(SEL)
Separator
(A/C)