Page 46
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
Figure 47.1
NOTICE:
• Offsetsfromthevertical,notexceeding45°,areallowed
perSection905(a)oftheUniformMechanicalCode
(UMC).
• Offsetsgreaterthan45°areconsideredhorizontalandare
alsoallowed,providingthehorizontalrundoesnotexceed
75% of the vertical height of the vent.
• Construction,clearanceandterminationmustbeincom-
pliancewiththeUMCTable9C.Thisinstallationmustalso
complywithNFPA211.
NOTICE:Topsectionsofchimneymustberemovabletoallow
maximum clearance of 13.5 feet (411cm) from ground level
for transportation purposes.
1. Anoutsideairinletmustbeprovidedforcombustionand
mustremainclearofleaves,debris,iceand/orsnow.It
must be unrestricted while unit is in use to prevent room
airstarvationwhichcancausesmokespillageandan
inabilitytomaintainare.Smokespillagecanalsoset
offsmokealarms.
2. Unitmustbesecuredtothemobilehomestructure.
Remove bolts from each side of insert and use plumbers
tape to secure to structure (a washer may be required).
Re-install bolts.
3. Unitmustbegroundedwith#8solidcoppergrounding
wireorequivalentandterminatedateachendwithN.E.C.
approved grounding device.
4. Thefactory-builtfireplacemustmeet(UM)84-HUD
requirements for outside combustion air supply to the
replacerechamberandthechimneymustbelistedto
UL103HToralistedUL-1777fulllengthsixinch(152mm)
diameter liner must be used. It must be equipped with a
sparkarrestorcapandtheoutsideairmustbeinstalled
on the insert.
5. Refer to page 31 of this manual for clearance to
combustiblesandoorprotectionsrequirements. All
clearances must be followed precisely.
6. Usesiliconetocreateaneffectivevaporbarrieratthe
location were the chimney or other component penetrates
to the exterior of the structure.
7. Followthechimneyandchimneyconnectormanufacturer’s
instructionswheninstallingtheuesystemforuseina
mobile home.
8. Burnwoodonly.Othertypesoffuelsmaygenerate
poisonous gases (e.g., carbon monoxide).
9. If unit burns poorly while an exhaust blower is on in home,
(i.e., range hood), increase combustion air.
10. Installation shall be in accordance with the Manufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Double Wall
Connector Pipe
CAUTION
THESTRUCTURALINTEGRITYOFTHEMOBILEHOME
FLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINED
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
•
Anysupportingmaterialthatwouldaffectthestructuralinteg-
rity
.
• NEVERINSTALLINASLEEPINGROOM.
Consumesoxygenintheroom.
WARNING
Asphyxiation Risk.
WARNING
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys.
Fumesorodormayresult
Fire Risk.
Asphyxiation Risk.
10
Mobile Home Installation