Radware VOYA-GRAND-MBK Lawn Mower User Manual


 
Page 46
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
Figure 47.1
NOTICE:
• Offsetsfromthevertical,notexceeding45°,areallowed
perSection905(a)oftheUniformMechanicalCode
(UMC).
• Offsetsgreaterthan45°areconsideredhorizontalandare
alsoallowed,providingthehorizontalrundoesnotexceed
75% of the vertical height of the vent.
• Construction,clearanceandterminationmustbeincom-
pliancewiththeUMCTable9C.Thisinstallationmustalso
complywithNFPA211.
NOTICE:Topsectionsofchimneymustberemovabletoallow
maximum clearance of 13.5 feet (411cm) from ground level
for transportation purposes.
1. Anoutsideairinletmustbeprovidedforcombustionand
mustremainclearofleaves,debris,iceand/orsnow.It
must be unrestricted while unit is in use to prevent room
airstarvationwhichcancausesmokespillageandan
inabilitytomaintainare.Smokespillagecanalsoset
offsmokealarms.
2. Unitmustbesecuredtothemobilehomestructure.
Remove bolts from each side of insert and use plumbers
tape to secure to structure (a washer may be required).
Re-install bolts.
3. Unitmustbegroundedwith#8solidcoppergrounding
wireorequivalentandterminatedateachendwithN.E.C.
approved grounding device.
4. Thefactory-builtfireplacemustmeet(UM)84-HUD
requirements for outside combustion air supply to the
replacerechamberandthechimneymustbelistedto
UL103HToralistedUL-1777fulllengthsixinch(152mm)
diameter liner must be used. It must be equipped with a
sparkarrestorcapandtheoutsideairmustbeinstalled
on the insert.
5. Refer to page 31 of this manual for clearance to
combustiblesandoorprotectionsrequirements. All
clearances must be followed precisely.
6. Usesiliconetocreateaneffectivevaporbarrieratthe
location were the chimney or other component penetrates
to the exterior of the structure.
7. Followthechimneyandchimneyconnectormanufacturer’s
instructionswheninstallingtheuesystemforuseina
mobile home.
8. Burnwoodonly.Othertypesoffuelsmaygenerate
poisonous gases (e.g., carbon monoxide).
9. If unit burns poorly while an exhaust blower is on in home,
(i.e., range hood), increase combustion air.
10. Installation shall be in accordance with the Manufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Double Wall
Connector Pipe
CAUTION
THESTRUCTURALINTEGRITYOFTHEMOBILEHOME
FLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINED
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
•
Anysupportingmaterialthatwouldaffectthestructuralinteg-
rity
.
• NEVERINSTALLINASLEEPINGROOM.
Consumesoxygenintheroom.
WARNING
Asphyxiation Risk.
WARNING
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys.
Fumesorodormayresult
Fire Risk.
Asphyxiation Risk.
10
Mobile Home Installation