VOYAGEUR GRAND Wood Insert
H. Air Controls
1. Start-Up Air Control
ThefunctionoftheStart-UpAirControlistoactivatethe
AutomaticCombustionControlsystem(ACC).
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward to the front of the appliance until it
stops. Figure 10.1.
• The air channel opens and allows air to enter the front of
the appliance for approximately 20-25 minutes.
• Theairchannelgraduallyshutsdownuntilitiscompletely
closed at the end of the 20-25 minutes.
• ThereisnowcontrolledbytheairsuppliedbytheBurn
RateAirControl.Figure 10.1.
• Thisfunctionshouldbeperformedeachtimeyoureload
the appliance.
Figure 10.1 Start-up and Burn Rate Air Controls
2. Burn Rate Air Control
• Theairsupply entersattheupperfrontofthe rebox,
near the top of the glass door.
• Thispreheatedairsuppliesthenecessaryfreshoxygen
to mix with the unburned gases, helping to create the
second, third and fourth combustion process.
• ThisairisregulatedbytheBurnRateAirControl.
• TherearefoursettingsHigh,Medium-High,Medium-Low
and Low.
• WhenthecontrolisraisedallthewayupitisontheHigh
setting and when pushed all the down it is on the Low
setting.
G. Automatic Combustion Control (ACC)
Typically,whenyoubuildare,youopentheaircontrolsfully
andmonitortheretopreventitfromgoingintoanoverre
situationand/orburningyourwooduptooquicklybeforeyou
shut down the air controls to the desired burn rate.
WhenusingtheAutomaticCombustionControl(ACC)system,
youdonothavetocontinuallymonitorthere.Onceyou
settheACCsystemitwillcontrolthereforyou.Followthe
instructions below to learn how to operate your stove with
ease.
I. Burn Rates and Operating Efciency
For maximum operating efciency
1. Burn dry, well-seasoned wood.
2. Followtheseburnrateinstructionsbelowandreferto
Figure 10.1.
*NOTE:
Theseareguidelines.Actualsettingsmayvarywithtype
of wood, chimney draft, altitude and other variables.
Burn Rates
1. Starting a Fire and Reloading
• OpenbothcontrolsfullybyraisingtheBurnRateAirCon-
trolallthewayupuntilitstopsandpushtheStart-upAir
Controlbackuntilitstops.
•
Theblowertendstocooltheappliance.Leavetheblower
off until the burn is well established, i.e., 30 minutes.
• Afterloadingtheappliancewithwoodandstartingthere,
set both controls to the desired setting by following the
burn rate instructions below.
2. High Burn Rate - Maximum Heat*
•
RaisetheBurnRateAirControlallthewayupuntilitstops
(topmarker)toafullyopenposition.
•
PushtheStart-UpAirControlallthewaybackuntilitstops
and leave it there.
•
Thissettingover-ridesthetimersystem(ACC)soyoumust
monitortherecloselywhileinthissetting.
3.
Medium-High Burn Rate - 15,000 to 30,000 BTU/hr*
• RaisetheBurnRateAirControlallthewayupuntilitstops
to a fully open position.
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward until it stops.
• Thisactivatesthetimersystem(ACC).
4.
Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr*
• RaisetheBurnRateAirControlup1/4fromlowestposi-
tion.
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward until it stops.
• Thisactivatesthetimersystem(ACC).
5. Low Burn Rate - Below 10,000 BTU/hr*
• LeavetheBurnRateAirControlatitslowestposition.
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward until it stops.
• Thisactivatesthetimersystem(ACC).
Burn Rate Control
ACC Start-up
Air Control
HIGH
LOW
To activate: Push back until it stops
and then pull forward until it stops