Radware VOYA-GRAND-MBK Lawn Mower User Manual


 
Page 10
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
H. Air Controls
1. Start-Up Air Control
ThefunctionoftheStart-UpAirControlistoactivatethe
AutomaticCombustionControlsystem(ACC).
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward to the front of the appliance until it
stops. Figure 10.1.
• The air channel opens and allows air to enter the front of
the appliance for approximately 20-25 minutes.
• Theairchannelgraduallyshutsdownuntilitiscompletely
closed at the end of the 20-25 minutes.
• ThereisnowcontrolledbytheairsuppliedbytheBurn
RateAirControl.Figure 10.1.
• Thisfunctionshouldbeperformedeachtimeyoureload
the appliance.
Figure 10.1 Start-up and Burn Rate Air Controls
2. Burn Rate Air Control
• Theairsupply entersattheupperfrontofthe rebox,
near the top of the glass door.
• Thispreheatedairsuppliesthenecessaryfreshoxygen
to mix with the unburned gases, helping to create the
second, third and fourth combustion process.
• ThisairisregulatedbytheBurnRateAirControl.
• TherearefoursettingsHigh,Medium-High,Medium-Low
and Low.
• WhenthecontrolisraisedallthewayupitisontheHigh
setting and when pushed all the down it is on the Low
setting.
G. Automatic Combustion Control (ACC)
Typically,whenyoubuildare,youopentheaircontrolsfully
andmonitortheretopreventitfromgoingintoanoverre
situationand/orburningyourwooduptooquicklybeforeyou
shut down the air controls to the desired burn rate.
WhenusingtheAutomaticCombustionControl(ACC)system,
youdonothavetocontinuallymonitorthere.Onceyou
settheACCsystemitwillcontrolthereforyou.Followthe
instructions below to learn how to operate your stove with
ease.
I. Burn Rates and Operating Efciency
For maximum operating efciency
1. Burn dry, well-seasoned wood.
2. Followtheseburnrateinstructionsbelowandreferto
Figure 10.1.
*NOTE:
Theseareguidelines.Actualsettingsmayvarywithtype
of wood, chimney draft, altitude and other variables.
Burn Rates
1. Starting a Fire and Reloading
• OpenbothcontrolsfullybyraisingtheBurnRateAirCon-
trolallthewayupuntilitstopsandpushtheStart-upAir
Controlbackuntilitstops.
•
Theblowertendstocooltheappliance.Leavetheblower
off until the burn is well established, i.e., 30 minutes.
• Afterloadingtheappliancewithwoodandstartingthere,
set both controls to the desired setting by following the
burn rate instructions below.
2. High Burn Rate - Maximum Heat*
•
RaisetheBurnRateAirControlallthewayupuntilitstops
(topmarker)toafullyopenposition.
•
PushtheStart-UpAirControlallthewaybackuntilitstops
and leave it there.
•
Thissettingover-ridesthetimersystem(ACC)soyoumust
monitortherecloselywhileinthissetting.
3.
Medium-High Burn Rate - 15,000 to 30,000 BTU/hr*
• RaisetheBurnRateAirControlallthewayupuntilitstops
to a fully open position.
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward until it stops.
• Thisactivatesthetimersystem(ACC).
4.
Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr*
• RaisetheBurnRateAirControlup1/4fromlowestposi-
tion.
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward until it stops.
• Thisactivatesthetimersystem(ACC).
5. Low Burn Rate - Below 10,000 BTU/hr*
• LeavetheBurnRateAirControlatitslowestposition.
• PushtheStart-UpAirControlallthewaybackuntilitstops
and then pull forward until it stops.
• Thisactivatesthetimersystem(ACC).
Burn Rate Control
ACC Start-up
Air Control
HIGH
LOW
To activate: Push back until it stops
and then pull forward until it stops