Page 14
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
O. Blower Operating Instructions
1. Initial (cold) startup: Openbothcontrolsfullybyrais-
ingtheBurnRateAirControlallthewayupuntilitstops
andPUSHtheStart-upAirControlbackuntilitstops.
Theblowertendstocooltheappliance.Leavetheblower
off until the burn is well established, i.e., 30 minutes.
2. High Burn Setting: Both controls are open. Burn Rate
AirControlispulledupandtheStart-upAirControlis
fully pushed in. Blower may remain on.
3. Medium-High Burn Setting*: BurnRateAirControl
is closed then opened to 1 inch to fully open (pull up).
Blower may remain on.
4. Medium-Low Burn Setting*: Burn RateAir Control
isclosedthenopenedto1/4inchto1/2inch(pullup).
Leave the blower off until the burn is well established, i.e.,
30 minutes.
5. Low Burn Setting*: BurnRateAirControlisclosed
(down position).
Leave the blower off until the burn is
well established, i.e., 30 minutes.
*NOTE:Forburnsettings3to5theStart-upAirControl
needsto bepushed in (Open)then pulledforward to
activatetheAutomaticCombustionControl(ACC).
NOTE: Formaximumefciencyandlowestemissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes.
6. Theblowerisequippedwitharheostat(speedcontrol).
The highest blower speed is obtained by turning the
rheostaton,thenadjustingbacktowards“OFF”asfar
aspossible withoutturning theblower off.Fora low
blowerspeed,turnthecontrolknobclockwiseasfaras
possible
Blower Controls Under Ash Lip
MANUAL: over-
rides the internal
snap disc
AUTO: Fan with turn ON/OFF
automatically and is controlled
by the internal Snap Disc
1. The blower will turn on/off automatically when set to
AUTO.Figure 14.1.
2. WhensettoMANUAL,thefanwillturnon/offonlywhen
youturnitonoroff.Thissettingover-ridestheinternal
snap disc.
3. Swingthegrilledownwardtoexposetheblowercon-
trols.AdjustthespeedofthefanbyturningtheHIGH/
LOWknobtothedesiredsetting.
N. Blower Control Box & Snap Disc
Operating Instructions
Figure 15.1
NOTICE!
DoNOToperateacirculatingfanwithincloseproxim-
ity, approximately 4 ft (1.2m), of appliance
•Canreverseairow,blowinghotairintoappliance
cavity.
•Candamageapplianceblowerduetooverheating.