Powermatic SLR12 Pole Saw User Manual


 
14
Maintenance
Before doing maintenance on
the machine, disconnect it from the electrical
supply by pulling out the plug or switching
off the main switch! Failure to comply may
cause serious injury.
Interior of oil tank must be kept clean at all
times.
The track of caterpillar chain must be kept
lubricated at all times by the machine's
lubrication system.
Oil should be checked weekly, and more added
if necessary. Use light 20-weight oil. Change the
oil after 2000 hours of operation. Insufficient oil
may cause fast wear of gears; excessive oil into
the gear reducer may cause oil leakage. Never
overfill the oil tank, and never use recycled oil.
Refill the oil in the gear reducer until the level
reaches over half its full capacity.
Properly clean chips and sawdust from your
machine after work operations are complete.
Never use your hands, use a brush or
compressed air.
Optional Accessory
Part No. Description
SLR12-700 Laser Assembly
Troubleshooting (Electrical)
Trouble Probable Cause Remedy
Power light won’t
come on (no power).
Power source not functioning. Check three phase power source.
Motor overload relay tripped. Reset overload relay.
Fuse burned out. Replace fuse.
Power light won’t
come on (lack of
phase).
Power source is insufficient. Check three phase power source.
YL-60P wire is broken. Replace YL-60.
Poor connection on magnetic switch. Replace magnetic switch.
Poor connection on terminals. Replace TB1, TB2.
Screw loosened. Tighten screw.
Motor runs
abnormally.
Motor jammed. Clean motor.
Magnetic switch damaged. Replace magnetic switch.
Motor damaged. Replace motor.
Motor won’t run.
Magnetic switch damaged. Replace magnetic switch.
Motor burned out. Replace motor.