Polaris P2000i Portable Generator User Manual


 
19
CONTROLS AND FEATURES
SMART Throttle Switch
The SMART throttle switch (K)
automatically reduces engine speed
when loads are shut off or disconnected.
The engine returns to the proper speed to
power the electrical load when
appliances are turned ON or reconnected.
Press the SMART throttle switch to the
OFF position to reduce voltage changes
when high electrical loads are
simultaneously connected or when using
the DC output.
DC Receptacle and Fuse
The DC receptacle (N) is protected
from an overload with a fuse. If the
DC circuit is overloaded, the 5 amp
fuse (M) will blow and power to the
DC receptacle will cease. The red
light on the DC panel will illuminate.
The fuse is located to the left of the
receptacle and is accessed by
snapping open the access door. See
details on page 35. Replace the fuse
with one of the same capacity. Using
a higher rated fuse may cause damage
to the generator alternator.
The DC receptacle charges 12V DC automotive-type batteries. The DC
charging output is not regulated. The 12V DC receptacle has no battery
overcharge protection function. Do not overcharge the battery.