69
[Note]
• The measurement range may vary by measurement conditions.
• Normal conditions: 20km visibility with slight shimmer.
• Good conditions: 40km visibility, overcast, no heat,no shimmer and moderate wind.
• Reflector sheet: PENTAX genuine reflector sheet (5cm x 5cm).
• Quick Mode,wich is effective only under Normal mode (1mm) setting,functions with
Prism and Reflectorless Sheet.It is incorporated in all X series models and effective
up to 500m.
• When Quick Mode is on, the EDM accuracy using prism and reflector sheet is
±(3+2ppm x D)mm. When automatic correction is activated in Quick Mode,the EDM
accuracy is ±(3 +10ppm x D)mm.
• EDM Measuring time varies according to distance to be measured and conditions of
the environment.
• Reflectorless:
- The measurement range and accuracy of Reflectorless are based on the condition
that laser beam is emitted perpendicular to the white side of the Kodak Gray Card.
- The measurement range may be influenced by the shape of the target and its
environment.
- The measurement range at TRACK mode is over 5m.
• The operating time becomes shorter under the low temperature, due to the
temperature dependence of the battery performance.
• The points that can be recorded in one job file are maximum 2,000 measuring points
(XYZ).The user can make up to 50 job files.Job history can be managed thanks to date
clock recorded in each job file.
12. DATA COLLECTOR
The instrument can communicate directly with a computer through the RS232C interface.
By use of a data collector you can automate data entry from the collection of survey data
to the transfer of the data to a computer. This is useful in saving time and protecting data
integrity.
About connection with data collector and the handling,please refer to an
“Instruction manual”of the data collector.
Connecting a data collector to a computer is different with every system.
Please contact your local dealer about them.