32
4. TURNING THE POWER ON
4.1 Turning the power on and off
Pressing the [POWER] key shows the initialscreen.
(The [POWER] key is also used to turn the power off.)
After a few seconds, it turns to Electronic vial
screen. Move the vials to center by adjusting
the leveling screws.
Pressing the [ENT] key views the angle and
distance measurement screen.
• The Auto Power Off function will automatically turn the power off if no operations are
performed for approximately 10 minutes.(Factory default setting)
• The [POWER] key is controlled by software in the instrument while it is working, and
this key is valid only when turning off causes no problem.
• The value displayed when the power was last time turned off will be displayed for the
horizontal angle.If this horizontal angle is not needed,please perform horizontal
angle 0 SET.
For details on resetting the horizontal angle 0 See "5.2"
For details on changing the horizontal angle from clockwise to
counterclockwise See "5.6"
For details on measuring the vertical angle See "5.5"
For details on distance measurement See "6 "
For details on the automatic power-off function See "8.9 12"
For details on the Electronic vial See "10.1"
ELECTRONIC VIAL
T.COMP.
ON
30”/1DIV
SENS.
LD POINT PLUM ADJ
H.angle
H.dst.
V.dst.
85° 39’ 40”
MEAS TARGET 0 SET DISP MODE
MODE A 15°C S 0