Pentair Amerlite Landscape Lighting User Manual


 
Rev. G • Rev. G • Rév. G 10-29-07 7 P/N • Núm/Pte. • Réf. 99360000
8. Replace light assembly into niche and tighten
special pilot screw.
WARNING
Use only the special pilot screw provided with this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided
could create an electrical hazard which could result
in death or serious injury to pool users, installers or
others due to electrical shock.
9. Fill pool until the underwater light is
completely submerged in water before
operating the light for more than 10 seconds.
Turn on main switch or circuit breaker, as
well as the switch which operates the
underwater light itself, to check for proper
operation.
A
Bolt and nut are to be tightened at approx. 45 degrees
from the pilot screw between the tabs on the face ring
as shown above.
45 degrees
Figure 3.
Figure 4.
SECTION IV. Amerlite Replacement Parts
Item Part Description
No. No.
1 79212100 Face ring, large plastic, for S/S only, white
1 79212165 Face ring, large plastic, for S/S only, gray
1 79212111 Face ring, large plastic, for S/S only, black
2 79104800 Pilot Screw, with captive gum washer, brass
2 619355 Pilot Screw, with captive gum washer, S/S
3 79110600 Face ring assembly, S/S
4 79111000 Uni-tension wire clamp assy.
5 79100100 Lens, clear, 8-3/8 in. dia., tempered
5 79100200 Lens, med. blue, 8-3/8 in. dia., heat resistant
6 79101600 Gasket, 8-3/8 in. lens
7 79101800 Floodlamp, med. base, 100 watt, 12 volt
7 79101900 Floodlamp, med. base, 300 watt, 12 volt
7 79102100 Floodlamp, med. base, 500 watt, 120 volt
7 79107600 Floodlamp, med. base, 300 watt, 120 volt
7 79102200 Floodlamp, med. base, 400 watt, 120 volt
78900700 Kwik-change lens cover, green
78900800 Kwik-change lens cover, blue
78900900 Kwik-change lens cover, red
78901000 Kwik-change lens cover, amber
1
2
3
4
5
6
7