Pelco C2432M-A Landscape Lighting User Manual


 
Pelco Installation Manual C2432M-A (12/03) 7
SPECIFICATIONS
ELECTRICAL
Input Voltage: 24 VAC (outdoor models only)
Input Power: 62 vA (for heater)
MECHANICAL
Construction
Back Box: Aluminum
Mounting Bracket: Steel
Lower Dome: Clear polycarbonate, 0.090 inch thick
Dimensions: See dimension drawing
GENERAL
Environment
In-Ceiling: Indoor only
Pendant: Indoor/outdoor, NEMA 4X, IP66 Rated
Operating Range
In-Ceiling: 32 to 140°F (0 to 60°C) intermittent operation; 32 to 122°F (0 to 50°C) continuous operation
Pendant
Without Heater: 32 to 140°F (0 to 60°C) absolute maximum operating temperature;
32 to 122°F (0 to 50°C) sustained maximum operating temperature
With Heater: (Assumes no wind chill factor; for detailed test conditions, contact Pelco.)
Maximum operating
temperature: 140°F (60°C) absolute maximum; 122°F (50°C) sustained maximum
Minimum operating
temperature: -60°F (-51.11°C) absolute minimum; minimal icing at -50°F (-45.56°C) sustained minimum;
prevents icing at -40°F (-40°C) sustained minimum; de-ices. 1 inch (2.5 mm) within 3 hours after power-up
Weight
Back Box
Unit
(without camera)
In-ceiling: 2.17 lb (.98 kg)
Pendant Indoor: 4.45 lb (2.02 kg)
Outdoor Pendant: 4.75 lb (2.15 kg)
Lower Dome
In-ceiling: 1.6 lb (.73 kg)
Pendant: 1.83 lb (.83 kg)
CAMERA
Maximum Camera and
Lens Size: 5.00 (L) x 2.75 (W) x 2.75 (H) (12.70 x 6.99 x 6.99 cm)
(Design and product specifications subject to change without notice.)
10.1
(25.65)
7.5
(19.05)
9.70
(24.64)
fl 6.13
(fl 15.57)
DUAL WALL
CONSTRUCTION
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES