7.0 Water Connections
Connect unit to system flow and return pipes using the two
15mm isolating valves (see fig. 2).
Note: To ensure effective venting of the heat exchanger the flow
pipe should be connected to the bottom connection of the heat
exchanger.
Note: For SLIM-LINE RC installations pipe-work must not be
routed directly underneath the unit as this will adversely affect
the operation of the integral room thermostat. If this cannot be
avoided, the pipe-work must be boxed to prevent heat rise.
Ensure system is flushed in accordance with recognised best
practice and a suitable inhibitor is added to the system as
necessary.
Open valves fully, check pipe connections for leaks and vent
the heat exchanger - see Commissioning Procedure.