Pulling-Out the Mast Sections
1. Grab hold of the main mast (Figure 34) and begin pulling
the mast sections upwards. Start with second mast, then
the third mast and finally the fourth.
2. From the main mast, pull the winch cable wire to release
the safety stopper pulley at the second mast.
Figure 34. Mast Sections
GLOBUG LIGHTING SYSTEM — MAINTENANCE
NOTE
If the winch cable wire cannot
be pulled because of breakage
of the wire itself, the
safety
stoppers
installed in the sec-
ond mast will lock automatically
at the places indicated by the
arrows in Figure 35.
3. Disconnect the winch cable wire from the fourth mast by
pulling it out.
4. Each mast section should be equally spaced about 12-
inches from the preceding mast section. See Figure 34.
Figure 35. Cable Release Access Point
5. To release the safety stopper without pulling the cable
wire when removing the second mast from the first (main
mast), insert a screwdriver (Figure 36) nearest the hole
where the latch is caught. Press down on the screwdriver
to lift the pulley inside the second mast upward. Re-
move the screwdriver lifting the second mast upwards
as the latch is being pulled back. The second mast should
now be able to be pulled out from the first mast.
Figure 36. Releasing the Safety Stop Latches
WARNING - Mast Service Safety
The mast sections are heavy and awkward to handle. Use
proper lifting devices and procedures when servicing the mast
and its components.