PAGE 36 — DCA-70SSJU SERIES — OPERATION AND PARTS MANUAL (STD) — REV. #5 (06/03/03)
DCA-70SSJU SERIES — PRE-SETUP
Figure 33. Engine Oil Dipstick
When checking the engine oil, be sure to check if the oil is
clean. If the oil is not clean, drain the oil by removing the oil
drain plug, and refill with the specified amount of oil as outlined
in the Isuzu Engine Owner's Manual. Oil should be warm
before draining.
Circuit Breakers
To protect the generator from an overload, a 3-pole, 110 amp,
main
circuit breaker is provided to protect the UVW output
terminals from overload. In addition two single-pole, 20 amp
GFCI
circuit breakers are provided to protect the GFCI
receptacles from overload. Three 50 amp
load
circuit breakers
have also been provided to protect the auxiliary receptacles
from overload. Make sure to switch
ALL
circuit breakers to
the "OFF" position prior to starting the engine.
Lubrication Oil
Fill the engine crankcase with lubricating oil through the filler
hole, but DO NOT overfill. Make sure the generator is level.
and verify that the oil level is maintained between the two
notches (Figure 33) on the dipstick. See Table 11 for proper
selection of engine oil.
API Service Classification CH-4
API Service Classification CG-4
API Service Classification CF-4
ACEA Specification E3
ACEA Specification E2
Other types of motor oils may be substituted if they meet
the following requirements:
WARNING:WARNING:
WARNING:WARNING:
WARNING:
ONLY properly trained personel who have
read and understand this section should refill
the double fuel tank system.
Use
#2 diesel fuel
.
Figure 34. Double Fuel Tank System
Fuel spillage on a
hot!
engine can cause
a
fire
or
explosion
. If fuel spillage occurs,
wipe up the spilled fuel completely to
prevent fire hazards.
NEVER!
smoke
around or near the generator.
DANGER:DANGER:
DANGER:DANGER:
DANGER:
Refilling the Fuel System
The DCA70SSJU Series genset may (if equipped with a trailer
or skid) have a
double fuel tank system
(Figure 34), which
consists of an
internal
generator fuel tank, and a
trailer
mounted
fuel tank. It is also possible the genset can be
equipped with a
skid mounted
fuel tank (Figure 35). The
skid type fuel system does not use the internal generator
fuel tank.
Use the instructions in this section that applies to your type
of fuel tank system.
ALWAYS
fill the fuel tank with clean and fresh
#2 diesel
fuel.
DO NOT fill the fuel tanks beyond their capacities.
Pay attention to the fuel tank capacity when replenishing
fuel.The fuel tank cap must be closed tightly after filling.
Handle fuel in a safety container. If the container does not
have a spout, use a funnel. Wipe up any spilled fuel
immediately.