Multiquip DCA-15SPX4 Portable Generator User Manual


 
PAGE 32 — DCA-15SPX4— OPERATION MANUAL — REV. #0 (02/17/09)
DCA-15SPX4 — GENERATOR START-UP PROCEDURE
Figure 33. Voltage Adjust Control Knob
7. The generator's AC-voltmeter (Figure 32) will display the
generator’s output in VOLTS. If the voltage is not within
the specified tolerance, use the voltage adjustment
control knob (Figure 33) to increase or decrease the
desired voltage.
Figure 32. Voltmeter
8. Place the
main
,
GFCI
, and
aux
. circuit breakers in the
ON position (Figure 34).
9. Observe the generator's ammeter (Figure 35) and verify
it reads the anticipated amount of current with respect
to the load. The ammeter will only display a current
reading if a load is in use.
Figure 35. Ammeter (Load)
10. The generator will run until manually stopped or an
abnormal condition occurs.
Figure 31. Ammeter (No Load)
6. The ammeter (Figure 31) will indicate
zero amps
with
no load applied. When a load is applied, the ammeter
will indicate the amount of current that the load is
drawing from the generator.
5. Set the Speed Control Switch to the RUN position
(Figure 30).
Figure 30. Speed Control Switch (RUN)
Figure 34. Main, GFCI, and Aux.
Circuit Breakers (ON)