PAGE 48 DCA-150SSKII PARTS AND OPERATION MANUAL REV. #2 (05/08/01)
4. Close all engine enclosure doors (Figure 45).
Figure 45. Engine Enclosure Doors
Figure 48. Off/Manual/Auto Switch (Manual)
7. After engine starts, verify that the "Engine Running"
status LED (Figure 49) on the Microprocessor Engine
Control Module (MPEC) display is "ON" (lit).
DCA-150SSKII GENERATOR START-UP PROCEDURE (MANUAL)
Figure 49. MPEC Engine Running Status LED
6. Place the Off/Manual/Auto switch (Figure 48) in the
MANUAL position (down). Observe that the engine begins
to crank.
5. When starting the generator in COLD weather conditions,
press and hold the engine preheat button (Figure 46)
until the pre-heat lamp (Figure 47) is lit (ON).
Figure 46. Engine Pre-Heat Button
Figure 47. Engine Pre-Heat Lamp
8. If the unit has an ignition switch(Figure 50), turn the
key to the right, until the engine starts. Then
release the key to 'Run'.
Figure 50. Ignition Switch (Run)
9. Pull and turn the engine throttle lever (Figure 51) to
increase the engine speed to high.
Figure 52. Idle Control (ON)
10. If the generator is equipped without the engine
throttle lever, set the idle control switch to the "ON"
position. (See figure 52)
Figure 51. Engine Throttle Lever (High)
Table of Contents