Makita G2800R Portable Generator User Manual


 
8. MAINTENANCE SCHEDULE
26
DAILY INSPECTION
Before running the generator, check the following service items:
Excessive vibration,noise
Clean air cleaner element
Safe surroundings
Enough clean engine oil
Leakage of gasoline and engine oil
Loose or broken bolts and nuts
Enough gasoline
PERIODIC MAINTENANCE
Periodic maintenance is vital to safe and efficient operation of your generator.
Check the table below for periodic maintenance intervals.
IT IS ALSO NECESSARY FOR THE USER OF THIS GENERATOR TO
CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION-
RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL
SYSTEM EFFECTIVE.
The emission control system consists of the following parts:
The maintenance schedule indicated in the following table is based on the normal
engine operation. Should the engine be operated in extremely dusty condition or in
heavier loading condition, the maintenance intervals must be shortened depending
on the contamination of oil, clogging of filter elements, wear of parts, and so on.
(1) Carburetor and internal
parts
(2) Cold start enrichment
system, if applicable
(3) Intake manifold, if
applicable
(4) Air cleaner elements
(5) Spark plug
(6) Magneto or electronic
ignition system
(7) Spark advance/retard
system, if applicable
(8) Exhaust manifold, if
applicable
(9) Hoses, belts, connec-
tors, and assemblies
MAINTENANCE, REPLACEMENT OR REPAIR OF THE EMISSION CONTROL DEVICES
AND SYSTEMS MAY BE PERFORMED BY ANY NONROAD ENGINE REPAIR ESTAB-
LISHMENT OR INDIVIDUAL.