BATTERY INSTALLTION (Electric starter model)
Recommended Battery: A capacity of 12V-24AH or larger.
Death, personal injury and/or property damage may occur unless instruc-
tions are followed carefully.
Use battery of recommended capacity.
Turn the starter switch to the "STOP" position when mounting or dis-
mounting battery. When mounting battery, connect the positive (+) cable
first and then the negative (
-
) cable to the battery. Be careful not to
short battery cables. When dismounting battery, disconnect negative (
-
)
cable first.
RED CABLE : To positive (+) terminal
BLACK CABLE : To negative (
-
) terminal
Should the connection be made in incorrect manner, the generator will
be broken.
Tighten bolts and nuts on terminals securely so they will not be loos-
ened by vibration.
Disconnect battery cables when charging battery.
WARNING
"HOW TO" INSTALL BATTERY (See "OPTIONAL PARTS")