Makita G12010R Portable Generator User Manual


 
(1) Make sure that the no-fuse breaker is
off.
(2) Turn the fuel cock to the vertical
(open) position
(3) Turn the key switch to the
"START"
position.
If the engine won't start, turn the
switch back to
"RUN" position and then
wait for approximately 10 seconds to
try it again.
NOTE :
You might have to keep the starter
running for at least 3 to 5 seconds,
since the engine incorporates the
mechanism in it where the ignition
circuit is activated by the increase of
hydraulic pressure.
In the following occasion, two or three
trials may be required for starting the
engine :
(1) The very first starting of a new
generator.
(2) After the refueling of the engine
which has been stopped due to fuel
shortage.
(3) Starting after the oil filter change.
(4) Warm the engine up for a minute or
two. Longer time would be needed
in cold weather.
START
RUN
START
STOP
RUN
STOP
11
5. OPERATING PROCEDURES
STARTING THE ENGINE
CLOSE
CLOSE
OPEN
Check the oil level before each operations. (See page 6)
Perform the specified Daily Inspection to see if it is in normal condition.
CAUTION
ON
OFF