Grounding the generator
-To ground the generator to the earth, connect the
grounding lug of the generator to the gounding spike
driven into the earth or to the conductor which has
been already grounded to the earth.
-
If such grounding conductor or grounding electrode
is unavailable, connect the grounding lug of the
generator to the grounding terminal of the using
electric tool or appliance.
CAUTION
Generator must be grounded when the electrical
appliance
is
grounded.
Failure to ground generator may lead to electric
shock.
DC
application (For charging
12V
battery only)
0
DC receptacle is used only for charging a 12V
battery.
0
Connection of battery charging cables
:
Using the attached
DC
plug, connect
its
positive and
negative terminals to the corresponding battery
terminals.
0
Battery charging procedures
:
-
Make the proper connection as mentioned above, be
careful not to make a wrong connection. Be sure to
disconnect all cables connected from battery to any
other appliance.
-
Remove all plugs from top of battery.
-
Check electrolyte level and add distilled water if
necessary, to bring the electrolyte level to the level
marked
"UPPER".
-
Start engine to charge battery.
The charging time varies depending on the condition of
-.
discharge. The specific gravity of a battery electrolyte indicates the state of charge in
each battery cell. While charging battery, check the specific gravity with a hydrometer,
using a thermometer to correct hydrometer reading for temperature.
A
corrected specific
gravity reading of 1.26 to 1.28 in all cells indicates a fully charged battery.
Example
:
In case of 12V-40Ah automobile battery, it takes
5
to 6 hours to bring a
completely discharged battery to a state of full-charge.
-