Table 8-5 Query code list
Header Data Description Reply
1 SY ? Reading modulation mode selected n
2 TS ? Reading signal selected to TS input n, p, q, r
3 CO ? Reading setting status of CN on (1), off (0) n
4 CN ? Reading setting status of C/N value i
5 CL ? Reading setting status of step to be set n
6 BO ? Reading setting status of BER measurement on (1), off (0) n
7 BR ? Reading BER value ne
8 BJ ? Reading judgement results ne, n
9 BU ? Reading setting status of upper limit for BER threshold value ne
10 BL ? Reading setting status of lower limit for BER threshold value ne
11 BI ? Reading setting status of BER measurement interval n, p
12 CH ? Reading setting status of channel n
13 RF ? Reading setting status of RF frequency i
14 DF ? Reading setting status of digit to be set n
15 LM ? Reading setting status of output level i
16 DL ? Reading setting status of digit to be set n
17 CK ? Reading selection status of reference signal n
18 GR ? Reading selection status of group n
19 GS n ? Reading setting status of begin and end addresses in each
group
n, p
20 CW ? Reading setting status of modulation n
Refer to each Option instruction manual for specified program code of option.