To compensate for fluctuation of the weather data (which may cause
the weather alarm to ring constantly if the measured reading is close to
the alarm level), a hysteresis function has been implemented for each
weather alarm.
For example, if the high temperature alarm is set to 77°F and the
temperature reaches 77°F, the alarm will be activated. If the
temperature then drops to 76.8°F (a change of less than 1.8°F) and
then increases to 77°F again, the data will blink, but no alarm will be
activated.
The temperature would have to drop below 75.2°F (with a pre-set hysteresis of 1.8°F) so that the alarm
can be produced again. Hysteresis values for the various weather data types are given in the table.
Note: The temperature or humidity data will keep flashing even after the weather alarm has been
switched off by a button press. The flashing value indicates that the current weather condition is out of the
pre-set weather alarm limit(s).
DISPLAY MODES
MODE 1
Press and release the SET button to toggle between Mode 1 and Mode 2 display:
Pressure history graph displays 24 hour history
Wind speed displayed in the wind section
MODE 2
Press and release the SET button to toggle between Mode 1 and Mode 2 display:
Pressure history graph displays 72 hour history
Wind gust displayed in the wind section
DATE OR SECONDS DISPLAY
Press the ▲/DATE button to toggle between display of the date or seconds
Hold the ▲/DATE button until the station beeps to resync with sensors
RAINFALL DISPLAY
Press and release the /RAIN button to view:
1-hour
24-hour
Past Week
Past Month
Total Rainfall
Hold the /RAIN button until the station beeps to resync with the gateway.
WEATHER FORECAST AND TENDENCY
Weather data Hysteresis
Temperature 1.8°F
Humidity 3% RH
Pressure 0.029 inHg
Wind speed 6.2 mph