Kohler CFI230G Outdoor Shower User Manual


 
24
CFI230G
5
CFI230G
COMPONENTS
5mm
3mm
Slider Rail
Water Delivery
System
Roller Securing Caps
Splashguard
Aligning
Roller
Blanking
Cap
Water Delivery
Top Caps
Water Delivery Wall
Jamb & Wall Channel
Glass Panel
x13
A
x3
C
x5
B
x13
3mm
6mm
OR
Fixed Head
Water Delivery
System
2m Pipe and
Connector
Electrical
Cable
TROUBLESHOOTING
The information below gives details on what you can do as a user should you encounter difficulties whilst
operating the shower.
If there is a problem with the shower control some of the push buttons will flash very fast.
Malfunction Cause Remedy
Push buttons are
flashing on the shower
control and / or the
shower will not operate
No flow or low flow rate
from the Shower Fittings
Drip from spray plate
assembly on handset
Incorrect shower
temperature
Water supply isolated
Damaged or broken cable
connection
Electrical supply isolated
or fuse blown
Digital Mixer Valve
breakdown
Spray plate assembly
blocked
Hose blocked or twisted
A small amount of water
may be retained in the
shower fitting after the
shower control has been
turned off. This may drain
over a few minutes
Digital Mixer Valve
malfunction
Maximum temperature
incorrectly set
Digital Mixer incorrectly
fitted
Check water supply
Check cable connections
Check electrical supply
Isolate product and turn
back on after 30 seconds
If the problem still
persists note the
sequence of the flashing
push buttons and
contact Customer
Services
Refer to Cleaning
Clear blockage or
release twist in hose
This is quite normal.
Changing the angle of
the shower fitting may
vary the draining time
Solenoid fault. May
require cleaning or
replacement. Contact
Customer Services
Refer to Commissioning,
Maximum temperature
setting
Make sure that the hot
and cold water supplies
are connected correctly
RH
LH
Door
Stop Vinyl
NOTE:
The Water Delivery
System is supplied
attached to the Wall
Jamb & Wall Channel