OPERATION
The spa will automatically begin to operate when electrical power is applied. There is no ON/OFF switch for the
spa system.
The control system has been designed so that by connecting the spa to its properly grounded power source and
pressing the mode button, the spa will function properly and safely at 100°F. When your spa is first actuated, the
display will alternately flash ECON, the current spa temperature, and COOL until the spa water is less than 15°F cooler
than the set temperature. During each filter cycle, the spa will heat to the set temperature.
Control Panel
The control panel is easy to use with fingertip control of all the spa's functions. Control of temperature, jets, blower
and spa light is readily accessible from within the spa.
MODE
LIQUID CRYSTAL
DISPLAY
WARM
JETS BLOWER
LIGHT
COOL
Temperature Controls
The current temperature is constantly shown on the
display. Press either or once to display the set
temperature. (The set temperature is designated by a
triangle on the left side of the display.) Each time either
button is pressed again, the set temperature will in-
crease or decrease depending upon which button is
pressed. After 3 seconds, the display will automatically
show the current spa temperature. Press any button to
reset the system in the rare instance of an overheat
condition.
Jets Control
Press the button once to activate the low-
speed jet operation. Press the button again for the high-
speed jet operation, and again to deactivate the jets.
The low-speed jet operation will start automatically
when the heater is turned on or when a filter cycle is
activated. When a freeze condition is detected, high
speed jets are automatically activated.
Whenever the low-speed is energized with this
button, it will automatically turn off after 4 hours of
operation. The high-speed automatically turns OFF
after 30 minutes.
Blower
The button starts and stops the blower for
aeration in the spa.
The blower will automatically turn OFF after 30
minutes of operation.
Light
The button activates and deactivates the spa
light.
The spa light will automatically turn OFF after 4
hours of operation.