Jacuzzi J - LX Hot Tub User Manual


 
30
LX Collection
11.0 Automatic Filtration Cycles
Your new spa includes a 8-hour circulation pump which lters the water
continuously. The circulation pump draws water through the skimmer bag
and one of two lter cartridges to effectively remove small debris in your spa.
Note: The 8-hour circulation pump system also supplies heated water to
the spa when the heater turns on. The pump is not programmable.
The control system activates a programmable “Standard” or “Economy”
ltration/heating cycle to remove larger debris missed by the 8-hour
circulation pump ltration system. These cycles utilize pump #1 low
speed and the second lter cartridge to quickly “skim” the water of large
debris and minimize their “bath-tub ring” effect. Apart from their skimming
benet, each mode also effects the operation of your spa’s heater. Refer
to Sections 11.1 and 11.2 below for additional information.
 
Standard ltration/heating modes are typically selected by customers in
cold climates where heat up times are extended due to lower ambient
temperatures. In these modes, the water temperature is regulated by the
set temperature, 8-hour circulation pump, jets pump 1, and heater which
turns on as needed. After the programmed set temperature is reached,
the heater turns off and the circulation pump continues to operate
24-hours to lter and clean your spa unless in summer logic; see Section
14.1, page 42.
 
Economy ltration/heating modes are typically selected by customers in
warm climates where heat up times are minimized due to higher ambient
temperatures. In these modes, the water temperature is regulated by the
set temperature, 8-hour circulation pump, jets pump 1, and heater only
while a programmed lter cycle is running (unless in summer logic; see
Section 14.1, page 42).
11.3 Lock Modes (L1-L2)
These modes are designed for use during spa service or to prevent
unauthorized use.
 
Press and hold both control panel WARMER ( ) and COOLER ( )
buttons at the same time, then release. Then press either WARMER
( ) or COOLER ( ) button to select ltration/heating mode F0-F6 or
lock modes L1-L2. During the ltration/heating cycle the jets pump 1 low
speed and circulation pump will activate.