Jacuzzi J - 270 Swimming Pool Vacuum User Manual


 
J-200
 
This wiring diagram is used for all J-230, J-270 and J-280 230V 50 Hz
Export spa models With or Without the Circulation Pump Option.
Power Supply
OZONATOR (OPTIONAL)
O
3
GRN
TB1
230 VAC 3-Wire Connection (50Hz, 1-Phase Service)
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST BE
APPROPRIATE PER NEC AND/OR LOCAL CODES
BLU
BLU
J6
BRN
J5
BRN
BLU
BLK
BLU
BRN
BLU
BRN
BLU BLU
BRN BRN
BRN
2
1
PRESSURE SWITCH
HI - LIMIT / FREEZE SENSOR
TEMPERATURE SENSOR
J1
J2
J3
F1
20A, 250V
SC-20
PUMP 1
PUMP 2
TRANSFORMER
230 VAC
J4
F1
7 6 2 4
HI
HI
LO
Control Panel
SPA LIGHT
J20
K1
K2
K3
K4
K5
K6 K7 K8
J21
J11
J12
J13
J14
J15
J16
J17
J18
J19
J7 J8
J9
J10
Heater
2.7 kW @
230 VAC
JP1
4
2
3
1
6 5
8 7
Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 20A Logic (Factory Default Setting)
JP1 1-2 OFF = 30A Logic
JP1 3-4 ON = 2 Pump Operation (Not used on J-230)
JP1 3-4 OFF = 1 Pump Operation
JP1 5-6 ON = 40A Logic (Remove JP1 1-2 Jumper)
(Not used on J-230)
JP1 5-6 OFF = Leave off for 20A or 30A Logic
JP1 7-8 ON = Celsius Temperature Display
JP1 7-8 OFF = Fahrenheit Temperature Displayv
Not used on J-230
BLU
BRN
C
CIRC.
PUMP
* Shown
with Optional
Circulation
Pump
Optional
LED Lighting
System DCU
OR
46