Jacuzzi J - 270 Swimming Pool Vacuum User Manual


 
J-200

120V/15A† 240V/30A† 240V/40A
Circuit Breaker: 15A†, 1-Pole 30A†, 2-Pole 40A
, 2-Pole
Number of Wires: 3 (15A GFCI
Cord US
Only*)
4 (Hard Wire
Only)
4 (Hard Wire
Only)
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 12A 21A 30A

(page 8).
In 15A/30A conguration, the heater will not operate while the jets
pump is running in high speed. The factory setting is 120V/15A.
In 40A conguration, remove jumper JP1-2 on the board, to allow the
heater to operate when the jets pump is running in high speed.
CAUTION (For 4-wire 240 VAC Heater Operation): Move the red
wire on the main terminal strip (TB1) from position #1 to position
#3. Make certain wires are connected exactly as shown in Figure
D (Page 18) . Failure to do so will result in

the manufacturer’s warranty.
Export J-270 and J-280 Models (50 Hz)
230V/20A* 230V/30A** 230V/40A***
Circuit Breaker: 20A* 30A** 40A***
Number of Wires: 3 3 3
Frequency: 50 Hz 50 Hz 50 Hz
Current Draw: 15A 23A 29A
*
In 20A conguration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
**
In 30A conguration, the heater will operate while one jets pump is
running in high speed. Note: pump 2 runs only in high speed.
***
In 40A conguration the heater will operate while both jets pumps
are running in high speed.
14