Jacuzzi J-335 Swimming Pool Vacuum User Manual


 
23
J-300
9.0 Control Functions
9.1 Control Panel
A. LED Display: Can
display current water
temperature (default
display), water
temperature set point,
selected filtration/
heating mode, and error
messages.
B. Warmer ( ) Button: Increases water temperature set point.
C. Cooler ( ) Button: Decreases water temperature set point.
D.  Button Options: Turns waterfall, footwell light,
lighted cup holders and backlit pillows on in unison. Press once for
high intensity; press a second time for medium intensity; press a third
time for low intensity; press a fourth time to turn off. The displayed
color is changed using the light mode button (E) below.
E. Light Mode Button: Selects one of 4 color modes for waterfall,
footwell, cup holders, and pillow lights. See page 26 for addition
information.
F. Jets 1 Button: Turns jets pump #1 on and off. Press once for low
speed; press a second time for high speed; press a third time to turn
pump off.
G. Jets 2 Button (J-335 to J-375): Turns high-speed jets pump #2 on
and off. Press once to turn pump #2 on; press a second time to turn
pump #2 off.
H. Heat Indicator: Lit when heater is on.
Operation Details
Temperature Adjustment: 65 to 104°F (18 to 40°C). Factory default
setting is 100°F (38°C).
Light Operation: All LED lights run for 2 hours, then automatically
shut off.
Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when
activated, then turn off automatically to conserve energy. Simply
press either jets button to continue operation for an additional 20
minutes.
HA
2-Pump Control Panel Shown
D
B
C
E
G
F