Husky 1800 Series Pressure Washer User Manual


 
Installation
9312 2-7
Pedestal Mount Pump
1. Screw 2" coupling onto threaded end of 2" standard pipe.
2. Slide cast iron pedestal base up over the unthreaded end of 2" standard pipe.
3. Screw 1" suction pipe into install-a-socket. Suction pipe should be long enough to allow 3"
clearance from bottom of tank. Apply gasoline-resistant pipe compound to male threads.
4. Insert 1" suction pipe into 2" pipe and screw install-a-socket into coupling on end of 2" pipe.
5. Assemble union onto lower end of 1" suction pipe conforming to your site's piping layout.
Note that the GASBOY base is provided with an opening on one side, so that an elbow can
be used and the suction brought out horizontally aboveground if desired, instead of straight
down through the island.
6. Slide base down to proper position at the lower end of the pedestal, tighten six set screws.
7. Screw the 2" male thread on the base of the pump into the upper end of the install-a-socket.
Apply gasoline pipe compound to all male threads.
8. Securely mount pedestal base to concrete. If the pump is not securely fastened to the
foundation, supply line leaks at unions and pipe joints may occur.
See the
Conduit
section for correct installation of electrical conduit. All underground piping
and swing joints are supplied by the customer. All metallic piping should be at least
Schedule 40 wrapped/coated black steel pipe with extra-heavy malleable iron screw type
fittings. Protect metallic piping in contact with the ground with a properly designed cathodic
protection system.