Husky 1800 Pressure Washer User Manual


 
24
PROBLEM OR CONCERN POSSIBLE CAUSE SOLUTION
Gun/Hose - Leaking water Gun/Hose will need to be replaced. Replace-
ment parts are not available for the Gun/Hose.
Email us at customerservice@huskypow
erwasher.com for assistance or order onli-
ne at www.huskypowerwasher.com.
Leaking Oil from Pump A small amount of leakage is
normal
If leakage occurs please contact use directly at cust
omerservice@huskypowerwasher.com.
Leaking water from bottom
of unit
Machine Inlet connection is de-
fective
Check the Machine Inlet at the front of the unit to
ensure that water is not leaking from it. If the con-
nection is leaking it will have to be replaced.
Contact us at customerservice@huskypo
werwasher.com or order a replacement
directly online at www.huskypowe-
rwasher.com .
Pump housing is leaking water
Email us at customerservice@huskypow
erwasher.com for assistance.
Low pressure Faucet not fully open or unit is not
receiving a full volume of water
Open the faucet all the way.
Not building maximum Pres-
sure
Screen Filter is clogged Clean the Screen filter as instructed in the section 5.4.
Irregular Pressure
Gun or Hose failure Replace Gun and/or Hose. Contact us at custome
rservice@huskypowerwasher.com or order
online at www.huskypowerwasher.com.
Kink in the Garden Hose or Hose
is wrapped on a storage wheel
Unwrap the Garden Hose and lay it out flat to
ensure that there are no kinks in the Hose.
Water leaking from either Hose
or Unit
Stop water from leaking before using the unit
or contact us if you need assistance.
Garden Hose length is too long Shorten the length of the Garden Hose. We recom-
mend a maximum length of 25 to 50 feet for City
water supply and 30 feet for Well water supply.
Clogged Nozzle Clean the Nozzle as instructed in section 5.2.
Air in Pump Let Pressure washer run with Gun trigger de-
pressed and Wand removed until a steady
stream of water is released.
No Wand attached to the front
of the Gun
Attach either the Turbo or Adjustable Wand to
the front of the Gun. (High Pressure in created
with the Wand and not the Gun).
No water coming out of Wand Clogged Nozzle Clean Nozzle as instructed in section 5.2.
Quick Connect is attached in-
correctly
See section 3.2. To Attach Quick Connect pro-
perly, keep the outer collar of the Quick Con-
nect held back while sliding the Quick Connect
all the way forwad against the Inlet Nipple and
then release the collar to lock it into place. (The
collar is spring loaded so if it is released too
soon it will not lock into place).
Sceen Filter is clogged Clean the Sceen filter as instructed in section 5.4.