Honeywell 6039 Portable Generator User Manual


 
12
Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level At Each Use
Change Oil *Every 100 hours or Every Season
Check Valve Clearance ***Every Season
Service Air Filter ** Every 200 hours or Every Season
Replace Spark Plug Every Season
Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
5.5 kW
Rated Power ...........................................................................5.5 kW**
Surge Power ...........................................................................6.8 kW**
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V ........................................................... 22.9 Amps**
Current @120V ............................................................ 45.8 Amps**
Rated Frequency ..................................................... 60 Hz @3600 RPM
Phase ................................................................................Single Phase
6.5 kW
Rated Power ...........................................................................6.5 kW**
Surge Power ...........................................................................8.1 kW**
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V ............................................................27.1 Amps**
Current @120V ............................................................ 54.2 Amps**
Rated Frequency ..................................................... 60 Hz @3600 RPM
Phase ................................................................................Single Phase
7.5 kW
Rated Power ...........................................................................7.5 kW**
Surge Power .......................................................................... 9.4 kW**
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V ............................................................31.3 Amps**
Current @120V ............................................................ 62.5 Amps**
Rated Frequency ..................................................... 60 Hz @3600 RPM
Phase ................................................................................Single Phase
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.
5.5 & 6.5 kW
Displacement ...............................................................................389cc
Spark Plug Type ................................ NHSP LDF7TC or Champion N9YC
Spark Plug Gap ............................. 0.028-0.031 inches (0.70-0.80 mm)
Spark Plug Part Number .....................................................0J00620106
Gasoline Capacity .........................................................5.8 U.S. Gallons
Oil Type....................................See Chart in “Adding Engine Oil” Section
Oil Capacity ....................................................................1 L (1.06 Qts.)
Run Time (50% Load) ...................................................................9 hrs.
7.5 kW
Displacement ...............................................................................420cc
Spar Plug Type ..................................NHSP LDF7TC or Champion N9YC
Spark Plug Gap ....................................................0.030 inch (0.76 mm)
Spark Plug Part Number .....................................................0J00620106
Gasoline Capacity .........................................................5.8 U.S. Gallons
Oil Type....................................See Chart in “Adding Engine Oil” Section
Oil Capacity ....................................................................1 L (1.06 Qts.)
Run Time (50% Load) ...................................................................8 hrs.
The Environmental Protection Agency (and California Air Resource
Board for generators certified to CA standards) require(s) that
this generator comply with exhaust and evaporative emission
standards. Locate the emissions compliance decal on the engine
to determine what standards the generator meets. This generator
is certified to operate on gasoline. The emission control system
includes the following components (if equipped):
Air Induction System Ignition System
~ Intake Pipe / Manifold ~ Spark Plug
~Air Cleaner ~ Ignition Module
Fuel System Exhaust System
~ Carburetor ~ Exhaust Manifold
~Fuel Tank / Cap ~ Muffler
~ Fuel Lines ~ Pulsed Air Valve
~ Evaporative Vent Lines ~ Catalyst
~Carbon Canister
The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section of this manual should
be made at least once each season. Follow the requirements in the
"Maintenance Schedule".
NOTE:
Once a year replace the spark plug and replace the air filter.
A new spark plug and clean air filter assure proper fuel-air
mixture and help the engine run better and last longer.
Maintenance