INSTALLATION
Check Electrical Service and Plug
In
service is 1 phase 220
V,
60
HAC,
30
Amp. WitKthe
Before plugging
in
the sprayer, be sure the electrical
ON-OFF switch
in
the OFF position, plug the power
extension cord,
it
must have
3
wires of at least 10
supply cord into
a
grounded outlet. If you use an
gauge (2.5
mm2)
and should not be over
100
ft
(30.3
m) long.
Install
Wheels and Handle
Slide the axle through the frame. Slide the wheels
and washers onto the axle and secure
in
place
with
cotter pins provided. Install the hub caps. Attach the
handle
with
the four screws, flat washers, lock
washers and nuts provided.
l,nstall
Hose
and Spray
Gun
Connect the spray hose to the spray gun by inserting
the pin at the end of the hose into the quick
disconnect coupler on the gun. Connect the hose to
the fluid outlet
in
the same way.
Remove the tape from the cap on top of the pump.
-
..
.
$.
Cleaning Accessories
'..
i
For spraying detergent or other cleaning solution, we
'
Accessories
and instruction manual 801-192 for
recommend
using
a
chemical injector kit. See
installation and operation.
For removing rust andold paint we recommend using
a water sandblaster.
See
Accessoriesand instruction
manual 801.190 for installation and operation.
Connect
To
Water Supply
CAUTION
plumbing code regarding cross-connection to
Before attaching to water supply. check local
water supply. Backflow check valve 801-133.
pump
in
a
direct supply system.
Do
not exceed
1
6OoF (7OOC) water temperature to
from your city water supply to the unit's
3/4
in.
Connect a hose with at least a 3/4 in. (19 mm)
ID
garden hose threaded inlet. The supply hose should
not be more than
50
ft.
(15
m) long.
NOTE:
For a direct supply system, your water
AT LEAST
5
GPM
(19
LITER/MINI.
source at the
unit
must
have a flow rate of
If your operating conditions are different from above.
assistance.
contact our Customer Service Department for