Genie S-80 Utility Vehicle User Manual


 
Part No. 43650 Genie S-80 & Genie S-85 15
Operator's ManualSecond Edition · Fifth Printing
Check the Tire Pressure
This procedure does not need
to be performed on machines
equipped with the foam-filled
tire option.
Bodily injury hazard. An over-
inflated tire can explode and could
cause death or serious injury.
Tip-over hazard. Do not use
temporary flat tire repair products.
To safeguard maximum stability, achieve
optimum machine handling and minimize tire
wear, it is essential to maintain proper pressure
in all air-filled tires.
1 Check each tire with an air pressure gauge. Add
air as needed.
Tire specifications
Tire size 15-22.5SAT
Pressure 100 psi
6.89 bar
The Schedule
There are five types of maintenance inspections
that must be performed according to a schedule
daily, quarterly, six months, annual, two year. To
account for repeated procedures, the
Scheduled
Maintenance Procedures Section and the
Maintenance Inspection Report
have been divided
into five subsectionsA, B, C, D and E. Use the
following chart to determine which group(s) of
procedures are required to perform a scheduled
inspection.
Inspection Table or Checklist
Daily or every 8 hours A
Quarterly or every 250 hours A + B
Six months or every 500 hours A + B + C
Annual or every 1000 hours A + B + C + D
Two year or every 2000 hours A + B + C + D + E
Maintenance Inspection Report
The maintenance inspection report contains
checklists for each type of scheduled inspection.
Make copies of the
Maintenance Inspection Report
to use for each inspection. Store completed forms
for three years.
MAINTENANCE
Scheduled Maintenance
The scheduled maintenance items must be
completed by a person trained and qualified to
perform maintenance on this machine according to
the procedures found in the service manual for this
machine.
Inspections and maintenance described below
require the qualified entity to record and retain
records of all inspections and maintenance items
for four years.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before placing the machine back into
service.