Genie NI 5421 Portable Generator User Manual


 
© National Instruments Corporation 25 NI 5421 Specifications
Delay from
Start Trigger to
CH 0 Analog
Output
Interpolation Factor Typical Delay Refer to t
s2
at
NI Signal
Generators
Help»Devices»
NI 5421»
NI <bus>-5421»
Triggering»
Trigger Timing.
Digital Interpolation Filter
disabled.
43 Sample Clock
Periods + 110 ns
2 57 Sample Clock
Periods + 110 ns
4 63 Sample Clock
Periods + 110 ns
8 64 Sample Clock
Periods + 110 ns
Delay from
Start Trigger to
Digital Data
Output
40 Sample Clock periods + 110 ns.
Trigger Exporting
Exported
Trigger
Destinations
A signal used as a trigger can be routed out to any
destination listed in the Destinations specification
of Table 9.
Exported
Trigger Delay
65 ns (typical). Refer to t
s3
at NI Signal Generators Help»
Devices»NI 5421»NI <bus>-5421»Triggering»Trigger
Timing.
Exported
Trigger Pulse
Width
>150 ns. Refer to t
s4
at NI Signal Generators Help»
Devices»NI 5421»NI <bus>-5421»Triggering»Trigger
Timing.
Table 8. (Continued)
Specification Value Comments