Generac Power Systems 75 Portable Generator User Manual


 
SSeeccttiioonn 22
MMAAJJOORR GGEENNEERRAATTOORR CCOOMMPPOONNEENNTTSS
elbow. The breather chamber contains a removable
oil vapor collector. Oil vapor is condensed on the col-
lector material and drains back into the crankcase,
which minimizes the amount of oil vapor entering the
breather.
CHECK BREATHER:
1. Disconnect breather tube and remove four screws and
breather. Discard gasket.
2. Check to see that reed valve is not deformed (Figure 2-8).
Note: Reed valve must form a complete seal
around vent hole.
3. Remove oil vapor collector and retainer.
4. Check collector for deterioration and replace if necessary.
INSTALL BREATHER:
1. Install oil vapor collector and retainer.
Note: Push oil vapor collector and retainer in until
it bottoms.
2. Install breather with new gasket (Figure 2-8).
a.Torque screws to 5-8 ft-lbs.
3. Assemble breather tube to intake elbow.
Page 11
CONTROL PANEL COMPONENT IDENTIFICATION
Figure 2-9. – Control Panel Components