Automatic Standby Generator Owner’s Manual 21
Figure 4-3: Oil Drain Location
4.4 — Changing the Engine Air Cleaner
1. With the generator shut down, remove the top lid.
2. Disengage the wire clip and remove the air cleaner access cover. See Figure 4-4.
3. Remove the old air filter and discard.
4. Thoroughly clean the air cleaner enclosure of any dust or debris while ensuring that none of the debris falls in to the engine intake.
5. Install a new air cleaner.
6. Install the air cleaner cover and engage the wire clip.
7. Install the enclosure top lid. Tighten fasteners securely.
8. Place generator in AUTO.
Figure 4-4: Air Filter Location
4.5 — Spark Plug
Reset the spark plug gap or replace the spark plug as necessary:
1. With the generator shut down, remove the top lid.
2. Clean the area around the base of the spark plug to keep dirt and debris out of the engine.
3. Gently pull the spark plug boot off of the spark plug. Remove the spark plug and check the condition. Install a new plug if the old one is worn
or if reuse is questionable.
Oil Drain Hose
Drain Hose
Retaining Clamp
Oil Drain Hose Cap
Oil Fill Cap/Dipstick
Battery
Battery Access
Panel