Exmark 000 & higher Lawn Mower User Manual


 
Maintenance
Maintenance Service
Interval
Maintenance Procedure
Every 500 hours
Replace the secondary air cleaner element (May need more often under severe conditions.
See the Engine Owner's Manual for additional information.)
Change the hydraulic lter and uid. (May need more often under severe conditions.)
Check the wheel hub slotted nut torque specications.
Check the wheel lug nuts.
Check the park brake adjustment.
Yearly
Grease the deck and pump idler pivots.
Grease the front caster pivots.
Periodic Maintenance
Check Engine Oil Level
Service Interval: Before each use or daily
1. Stop engine and wait for all moving parts to stop.
Make sure unit is on a level surface.
2. Check with engine cold.
3. Clean area around dipstick. Remove dipstick
and wipe oil off. Reinsert the dipstick according
to the engine manufacturer's recommendations.
Remove the dipstick and read the oil level.
4. If the oil level is low, wipe off the area around the
oil ll cap, remove cap and ll to the “FULL”
mark on the dipstick. Exmark 4-Cycle Premium
Engine Oil is recommended; refer to the Engine
Owner's manual for an acceptable alternative. Do
Not overll.
Important: Do Not operate the engine with the
oil level below the “LOW” (or “ADD”) mark on
the dipstick, or over the “FULL” mark.
Check Battery Charge
Service Interval: As required
WARNING
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to the State of
California to cause cancer and reproductive
harm. Wash hands after handling.
Allowing batteries to stand for an extended period of
time without recharging them will result in reduced
performance and service life. To preserve optimum
battery performance and life, recharge batteries in
storage when the open circuit voltage drops to 12.4
volts.
Note: To prevent damage due to freezing, battery
should be fully charged before putting away for
winter storage.
Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery in
the table and charge the battery for the recommended
time interval to bring the charge up to a full charge
of 12.6 volts or greater.
Important: Make sure the negative battery cable
is disconnected and the battery charger used for
charging the battery has an output of 16 volts and
7 amps or less to avoid damaging the battery (see
chart for recommended charger settings).
Voltage
Reading
Percent
Charge
Maximum
Charger
Settings
Charging
Interval
12.6 or
greater
100%
16 volts/7
amps
No
Charging
Required
12.4 12.6 75–100%
16 volts/7
amps
30 Minutes
12.2 12.4 50–75%
16 volts/7
amps
1 Hour
12.0–12.2 25–50%
14.4 volts/4
amps
2 Hours
11.7–12.0 0–25%
14.4 volts/4
amps
3 Hours
11.7 or less
0%
14.4 volts/2
amps
6 Hours or
More
30