1-1/4" THREADED
STUD (2)
CEILING COVER
KNURLED KNOB (2)
LOCKWASHER (2)
HANGER
BRACKET
OUTLET
BOX
HANGER BALL/DOWNROD
ASSEMBLY
1-1/4" THREADED
STUDS (2)
HANGER
BRACKET
OUTLET BOX
RECEIVER
CEILING
COVER
Figure 16
WHITE SUPPLY WIRE
BLACK FAN WIRE
SW105 RECEIVER
WHITE FAN WIRE
BLUE RECEIVER WIRE
BLUE FAN WIRE
BLACK SUPPLY
WIRE
WHITE RECEIVER WIRE
BLACK RECEIVER WIRE
BLACK/WHITE
RECEIVER WIRE
YELLOW RECEIVER WIRE
DOWNROD
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
4. After connections have been made, separate the
white and green wires from the black, blue and
yellow wires.
5. Carefully turn the wires upward and insert them up
through the open side of the hanger bracket and
into the outlet box. Push the green equipment/earth
ground and white grounded neutral wires into one
side of the outlet box; push the black, blue and
yellow ungrounded wires into the other side of the
outlet box.
Figure 15
6. Screw the two 1-1/4” threaded studs (supplied) into
the tapped holes in the hanger bracket (Figure 16).
7. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 17).
8. Secure the ceiling cover in place by installing two
lockwashers and two knurled knobs (supplied)
(Figure 26). Tighten the knurled knobs securely
until the ceiling cover fits snugly against the ceiling
and the hole in the ceiling cover is clear of the
downrod.
9. Your ceiling fan in now installed and wired and
ready for use.
Figure 17
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
WARNING
9
U.L. Model No.: CF3100U.L. Model No.: CF3100